<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Iscsi on sigtar.com</title>
		<link>https://sigtar.com/tags/iscsi/</link>
		<description>Recent content in Iscsi on sigtar.com</description>
		<generator>Hugo</generator>
		<language>en-nz</language>
		
		
		
		
			<lastBuildDate>Mon, 11 Jul 2011 00:00:00 +1200</lastBuildDate>
		
			<atom:link href="https://sigtar.com/tags/iscsi/index.xml" rel="self" type="application/rss+xml" />
			<item>
				<title>solaris - storage server</title>
				<link>https://sigtar.com/2011/07/11/solaris-storage-server/</link>
				<pubDate>Mon, 11 Jul 2011 00:00:00 +1200</pubDate>
				<guid>https://sigtar.com/2011/07/11/solaris-storage-server/</guid>
				<description>&lt;p&gt;&lt;a href=&#34;http://p2v.it/2010/04/15/a-next-generation-multiprotocol-storage-for-your-homelab-on-a-budget-part-1/&#34;&gt;http://p2v.it/2010/04/15/a-next-generation-multiprotocol-storage-for-your-homelab-on-a-budget-part-1/&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;Setup iSCSI target using comstar &amp;ndash; &lt;strong&gt;pkg install -v storage-server pkg install pkg:/SUNWiscsit svcadm enable stmf svcadm enable svc:/network/iscsi/target:default itadm create-target&lt;/strong&gt; &lt;strong&gt;reboot &amp;ndash; -r&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Create the iSCSI store &amp;mdash; &lt;strong&gt;zfs create -V 100G DataPool/TestDatastore1 sbdadm create-lu /dev/zvol/rdsk/DataPool/TestDatastore1 stmfadm create-hg ESX4-group stmfadm add-hg-member -g ESX4-group wwn.2100001b329711bd wwn.2101001b32b711bd stmfadm add-view -h ESX4-group -n 0 600144F03EBEC50000004BA86E460001 stmfadm list-lu -v&lt;/strong&gt;&lt;/p&gt;</description>
			</item>
			<item>
				<title>P4000 / Lefthand and Windows DSM (MPIO)</title>
				<link>https://sigtar.com/2011/05/04/p4000-lefthand-and-windows-dsm-mpio/</link>
				<pubDate>Wed, 04 May 2011 00:00:00 +1200</pubDate>
				<guid>https://sigtar.com/2011/05/04/p4000-lefthand-and-windows-dsm-mpio/</guid>
				<description>&lt;p&gt;Steps to setup MPIO round robin and DSM with P4000 / Lefthand nodes&lt;/p&gt;&#xA;&lt;p&gt;This example is windows 2008 with 2 x 1gbit nics&lt;/p&gt;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Install HP DSM driver onto windows 2008  (this should also install MPIO feature on windows 2008)&lt;/li&gt;&#xA;&lt;li&gt;Setup 2 x IP&amp;rsquo;s on windows host - storage subnet (used with MPIO)&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Confirm you can ping target from both (enable one at a time - ensure there is no routing on your other nics)&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;/li&gt;&#xA;&lt;li&gt;Provision storage and allow server read / write access to windows server (via initiator name)&lt;/li&gt;&#xA;&lt;li&gt;Open iSCSI on windows 2008&lt;/li&gt;&#xA;&lt;li&gt;Put in IP of target in discovery tab&lt;/li&gt;&#xA;&lt;li&gt;On first tab confirm that iSCSI drive is presented to host&lt;/li&gt;&#xA;&lt;li&gt;Click &amp;ldquo;connect&amp;rdquo; - check both auto-connect and use MPIO&#xA;&lt;ol&gt;&#xA;&lt;li&gt;click advanced - chose MS iSCSI initiator, choose first IP and target IP. Click o.k. / o.k&lt;/li&gt;&#xA;&lt;li&gt;click advanced - chose MS iSCSI initiator, choose second IP and target IP. Click o.k. / o.k&lt;/li&gt;&#xA;&lt;li&gt;Repeat above per additional Nic&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;/li&gt;&#xA;&lt;li&gt;Confirm via &amp;ldquo;devices&amp;rdquo; that there is x (as many targets as nics) targets per disk&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Within devices choose MPIO - change from vendor specific to &amp;ldquo;round robin&amp;rdquo;&#xA;&lt;ol&gt;&#xA;&lt;li&gt;Note : read / write access to LUN is required when using &amp;ldquo;round robin&amp;rdquo; MPIO opposed to the default &amp;ldquo;vendor specific&amp;rdquo; which works with read only access. Else you will get an error - &amp;ldquo;not supported&amp;rdquo;&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;/li&gt;&#xA;&lt;li&gt;Repeat above per &amp;ldquo;device&amp;rdquo;&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;/li&gt;&#xA;&lt;li&gt;Confirm on Lefthand / P4000 CMC that the LUN has one connection per initiator Nic, and that each connection also has its DSM children (visible in CMC if working).&lt;/li&gt;&#xA;&lt;/ol&gt;&#xA;&lt;p&gt;Confirm that the connection are as expected&amp;hellip;&lt;/p&gt;</description>
			</item>
			<item>
				<title>vmware - measuring iscsi write performance</title>
				<link>https://sigtar.com/2010/05/07/vmware-measuring-iscsi-write-performance/</link>
				<pubDate>Fri, 07 May 2010 00:00:00 +1200</pubDate>
				<guid>https://sigtar.com/2010/05/07/vmware-measuring-iscsi-write-performance/</guid>
				<description>&lt;p&gt;I picked this trick up off vmware support. If you&amp;rsquo;ve got your iscsi all setup you can drop to the shell (either ssh or console) and do this to measure your average write throughput.&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;time vmkfstools -c 10G /vmfs/volumes/san_vmfs/my_vm/fat_disk.vmdk -d eagerzeroedthick&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Try larger a larger disk if this is too quick (free space permitting)&lt;/p&gt;&#xA;&lt;p&gt;Essentially this will initiate the host to create a fat disk in the location above. You will then get a time recorded on how long it takes to execute this command. Then you can use your maths skill to work out the transfer rate&amp;hellip;&lt;/p&gt;</description>
			</item>
			<item>
				<title>vSphere and Multipathing iSCSI</title>
				<link>https://sigtar.com/2010/02/04/vsphere-and-multipathing-iscsi/</link>
				<pubDate>Thu, 04 Feb 2010 00:00:00 +1300</pubDate>
				<guid>https://sigtar.com/2010/02/04/vsphere-and-multipathing-iscsi/</guid>
				<description>&lt;p&gt;This is just a quick reference to create a multiplathing iSCSI setup&amp;hellip;&lt;/p&gt;&#xA;&lt;p&gt;Create two virtual kernel switches, one called &amp;ldquo;iSCSI-1&amp;rdquo; and the other called &amp;ldquo;iSCSI-2&amp;rdquo; (and so on if you have more nics)&lt;/p&gt;&#xA;&lt;p&gt;Then per kernel portgroup ensure that only one of the nics is active. For the &amp;ldquo;iSCSI-1&amp;rdquo; portgroup configure it to override the virtual switch settings and move nic 0 to active and nic 1 to &lt;strong&gt;unused&lt;/strong&gt;. For the &amp;ldquo;iSCSI-2&amp;rdquo; portgroup configure it to override the virtual switch settings and move nic 1 to active and nic 0 to &lt;strong&gt;unused&lt;/strong&gt;.&lt;/p&gt;</description>
			</item>
			<item>
				<title>OpenSolaris - iSCSI</title>
				<link>https://sigtar.com/2009/11/13/iscsi-in-opensolaris/</link>
				<pubDate>Fri, 13 Nov 2009 00:00:00 +1300</pubDate>
				<guid>https://sigtar.com/2009/11/13/iscsi-in-opensolaris/</guid>
				<description>&lt;p&gt;Want iSCSI in opensolaris?&lt;/p&gt;&#xA;&lt;p&gt;Grab SUNWiscsitgt via package manager.&lt;/p&gt;&#xA;&lt;p&gt;enable the server via svcadm;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;svcadm enable iscsitgt&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;create your zfs iscsi pool;  (this command will limit iscsi drive to 500GB in size)&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;zfs create -V 500G tank/iscsi&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;set isci on via zfs command;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;zfs set shareiscsi=on tank/iscsi&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;check that target is up and running;&lt;/p&gt;&#xA;&lt;p&gt;&lt;strong&gt;iscsitadm list target -v&lt;/strong&gt;&lt;/p&gt;&#xA;&lt;p&gt;Done. Should be able to connect via ip from another machine. I have not covered CHAP or any client side configuration. Assumed isolated LAN.&lt;/p&gt;</description>
			</item>
			<item>
				<title>ESX - network utilization</title>
				<link>https://sigtar.com/2009/08/22/esx-network-utilization/</link>
				<pubDate>Sat, 22 Aug 2009 00:00:00 +1200</pubDate>
				<guid>https://sigtar.com/2009/08/22/esx-network-utilization/</guid>
				<description>&lt;p&gt;One of the best articles i have found on this subject is here : &lt;a href=&#34;http://blog.scottlowe.org/2008/07/16/understanding-nic-utilization-in-vmware-esx/&#34;&gt;http://blog.scottlowe.org/2008/07/16/understanding-nic-utilization-in-vmware-esx/&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;There is some additional information here on setting up an etherchannel on the cisco side : &lt;a href=&#34;http://blog.scottlowe.org/2006/12/04/esx-server-nic-teaming-and-vlan-trunking/&#34;&gt;http://blog.scottlowe.org/2006/12/04/esx-server-nic-teaming-and-vlan-trunking/&lt;/a&gt;&lt;/p&gt;&#xA;&lt;p&gt;This can be handy if you need a single VM to use both physical nics in a load-balanced manner - both outbound and &lt;strong&gt;inbound&lt;/strong&gt;. Of course its not really that simple though. This will really only add a benefit if the VM is communicating to &lt;em&gt;multiple&lt;/em&gt; destinations (using ip hash - a single destination from a single VM with one IP will always be limited to the same physical nic).&lt;/p&gt;</description>
			</item>
	</channel>
</rss>
